<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>http://sop.mse.mtu.edu/index.php?action=history&amp;feed=atom&amp;title=Flammability_Testing</id>
	<title>Flammability Testing - Revision history</title>
	<link rel="self" type="application/atom+xml" href="http://sop.mse.mtu.edu/index.php?action=history&amp;feed=atom&amp;title=Flammability_Testing"/>
	<link rel="alternate" type="text/html" href="http://sop.mse.mtu.edu/index.php?title=Flammability_Testing&amp;action=history"/>
	<updated>2026-06-01T16:22:35Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.37.2</generator>
	<entry>
		<id>http://sop.mse.mtu.edu/index.php?title=Flammability_Testing&amp;diff=201&amp;oldid=prev</id>
		<title>Gcanzalo: Copied from old</title>
		<link rel="alternate" type="text/html" href="http://sop.mse.mtu.edu/index.php?title=Flammability_Testing&amp;diff=201&amp;oldid=prev"/>
		<updated>2022-05-24T18:57:53Z</updated>

		<summary type="html">&lt;p&gt;Copied from old&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;[[Category: SOP]]&lt;br /&gt;
&lt;br /&gt;
The following is an SOP on writing a flammability testing specifically for magnesium however can be used for other metals with similar ignition temperatures and limited EHS risks. &lt;br /&gt;
&lt;br /&gt;
=Loss Prevention (Saftey)=&lt;br /&gt;
* Magnesium burns at temperatures above 2000 °C, so care must be taken to avoid contact with the metal while burning&lt;br /&gt;
*Mg will give off a bright light that can cause eye damage welding masks or special eye protection should be used. Alternatively, avoid looking at the burning magnesium.&lt;br /&gt;
*Clothing should not be very flammable in case of sparking&lt;br /&gt;
* Water WILL NOT extinguish the fire but will make it worse. A bucket of sand or ideally a MET-L-X Class D fire extinguisher should be kept on hand to extinguish an out of control fire.&lt;br /&gt;
*Sand should be used below the testing environment in case the sample falls&lt;br /&gt;
&lt;br /&gt;
=Procedure=&lt;br /&gt;
# Gather clamp, ring stand, ring support, sand, propane torch, large baking tray, something to hold the torch in place (NOT UNDER THE Mg), and a stopwatch.&lt;br /&gt;
#Set up the stand and propane torch as shown in the picture. This set up will be set up on the baking tray filled with about 2&amp;quot; of sand. [[File:Flame.png|right|frame|Flammability Testing Set-up]]&lt;br /&gt;
#Place the Mg wire into the clap such that the end of the wire will be covered in flame once the torch is ignited.&lt;br /&gt;
#Have a second person hold the stopwatch while following directions to light the torch.&lt;br /&gt;
#The flame should be consistent between measurements so take note of the flame used for the initial test and adjust subsequent tests to match.&lt;br /&gt;
#Once the flame is lit and is in contact with the Mg wire, the stop watch should be started.&lt;br /&gt;
#Watch the Mg wire and once a white light is observed the stopwatch should be stopped. &lt;br /&gt;
#Turn off the torch and let the Mg wire burn out, taking care not to give the Mg wire fuel to start a larger fire. &lt;br /&gt;
#Once Mg has burned out and is either in the sand or still in wire form remove from clamps and sand.&lt;br /&gt;